Different Timing Applications of Intra-aortic Balloon Counterpulsation for Patients with Acute Myocardial Infarction Complicated by Pump Failure
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Aim To investigate the application opportunity of intra-aortic balloon pump (IABP) for patients with acute myocardial infarction (AMI) complicated by pump failure and its influence on therapeutic efficacy for these patients.Methods 85 patients with acute myocardial infarction complicated by pump failure were randomly divided into two groups according to application opportunity of IABP. Immediate IABP group (43 cases) underwent the IABP surgery immediately after diagnosis. Necessary IABP group (42 cases) after positive drugs therapy, whose systolic blood pressure remains <90 mmHg, underwent IABP surgery. And all the patients underwent emergency percutaneous coronary intervention (PCI) as soon as possible. The difference of door-to-balloon time, survival rate of the 1 week and 3 month postoperative in two groups were compared, left ventricular ejection fraction (EF) of 1 day and 3 month were measured. Results Door-to-balloon time of necessary IABP group was significantly greater than the immediate IABP group (96.7±31.2 min vs 78.3±35.6 min, P<0.05). The survival rate of necessary IABP group after 3 months was significantly lower than a week postoperative (57.1% vs 69.0%), and lower than instantly IABP group (57.1% vs 67.4%), there were significant differences (P<0.05). EF of two groups after three months were continuously decreased, the necessary IABP group declined more than the immediate IABP group (7.6%±3.5% vs 4.2%±3.1%, P<0.05). Conclusion Early use of IABP for patients with acute myocardial infarction complicated by pump failure, can shorten revascularization time, reduce mortality and protect left ventricular systolic function.

    Reference
    Related
    Cited by
Get Citation

PAN Hong-Wei, GUO Yin, ZHEN Zhao-Fen, HE Jin, ZHANG Yu, LIU Zheng-Yu, HU Yong-Jun,,PENG Jian-Qiang. Different Timing Applications of Intra-aortic Balloon Counterpulsation for Patients with Acute Myocardial Infarction Complicated by Pump Failure[J]. Editorial Office of Chinese Journal of Arteriosclerosis,2014,22(1):65-68.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:May 29,2013
  • Revised:
  • Adopted:
  • Online:
  • Published:
Article QR Code